ABS Pumps - ABS lifting station Sanisett 1 and 2
| Type key Example: |
ABS Sanisett 1 and 2 |
Sanisett |
Synthetic Pumping Station |
| 1 or 2 |
Single Pump or Twin Pump |
| Pump Type: |
|
| Robusta |
Light Drainage Pump (10 mm solids) |
| Coronada |
Light Drainage Pump (10 mm solids) |
| MF |
Light Wastewater Pump (upto 60 mm solids) |
Piranha |
Grinder Pump |
| Properties: |
|
| Flow up to: |
30 m³/h |
| |
Head, max 21m |
| Head, Max: |
21m |
|
|
|
ABS Sanisett 1 and 2 - lifting station
Synthetic, single or twin pumping station, for the effective dewatering of buildings and areas below the sewer level in accordance with EN 12050-2. Designed as a complete wastewater sump for above- or below-ground installation and for fitting with ABS pumps from the Robusta, Coronada, Piranha and MF ranges. The Sanisett 2 is suitable also for the pumping of sewage containing faecal matter outside of areas covered by EN when installed using Piranha pumps.
Features
- Globular shape for extra strength. Below-ground version has manhole cover with floor run-off and option of odour lock with aeration and venting. Above-ground version with plastic lid (accessory).
- Universally adjustable in height and can be swivelled, thus allowing easy alignment with floor levels and tiling patterns, independent of the inflow or direction of the discharge lines.
- Sanisett 1 for one KS version pump (Coronada, Piranha, MF) or pump with built-in level control (Robusta).
- Sanisett 2 for two non-KS pumps. Separate KS level control system, with support bracket for discharge line junction piece and KS float switches.
- Two inflow ports at 90º offset (DN 100/150) for DIN push-on connection. One port DN 70 for venting and use as a cable duct (supplied as standard with plug/cable inlet seal). One discharge port DN 50 with 63 mm Plasson adaptor.
- Plastic cover for protection of the floor grating during installation work supplied as standard.
- Heads up to 20 m with Piranha 08/09 pumps.
- Maximum allowable temperature of medium 40 ºC, short term to 60 ºC (max. 5 minutes).
Tank
Synthetic, corrosion-resistant, gas- and odour-tight tank, in accordance with EN 12050-2. Supplied as standard with cover, seals, junction piece, pipe adapters and support bracket. Pump(s) and installation kit not included.
Capacity: 180 litres
Weight: 14 kg (without pump)
Motor
Water pressure sealed, squirrel cage 2-pole induction motor.
Insulation: Class F to 155 ºC
Protection type: IP 68
Pump Types
- ABS Robusta light drainage pump 200 WTS, for pumping of ground and rain water, water from hand-basins, and washing machine effluent. (10mm solids passage.)
- ABS Coronada light drainage pump 250 WKS. For wastewater (as Robusta above), but suitable also for aggressive ground water thanks to the stainless steel pump housing and a mechanical seal for shaft sealing. (10mm solids passage.)
- ABS light wastewater pump MF 154 W to 804 D, for wastewater with large solid particles present. (Up to 40 mm solids passage.)
- ABS Piranha submersible grinder pump 08/09 with heads up to 20 m which can be used to cut up and pump wastewater containing solids.
Materials
| Description |
Material |
Tank |
Polyethylene |
| Robusta |
|
| Pump Housing |
PP |
| Rotor Shaft |
Stainless steel 1.4028 (AISI 420) |
| Impeller |
PA |
| Seals |
NBR |
Cable |
Neoprene |
| Coronada |
|
| Pump Housing |
Stainless steel 1.4301 (AISI 304) |
| Motor Housing |
Stainless steel 1.4301 (AISI 304) |
| Rotor Shaft |
Stainless steel 1.4305 (AISI 303) |
| Impeller |
PPO |
Cable |
Neoprene |
| Piranha 08/09 and MF |
|
| Upper Lid |
Stainless steel 1.4301 (AISI 304) |
| Motor Housing |
Cast iron EN-GJL-250 |
| Rotor Shaft |
Stainless steel 1.4021 (AISI 420) |
| Volute |
Cast iron EN-GJL-250 |
| Impeller * |
Polyamide |
Seal |
Neoprene |
| Fasteners |
Stainless steel 1.4401 (AISI 316) |
|
|
|
* Piranha 09: cast iron EN-GJL-250
Downloads
|
ABS Pumps Product Links
ABS Pumps Only
ABS Pumps Lifting Stations
More Links
Resources
Contact
|